The C8051F040 still has a UART0 serial port for printing output or debugging information on a terminal. As in all
MPS labs the port must be configured with a counter to set the BAUD rate. The C8051F040 does not have a PLL
so the crystal oscillator frequencies are greatly limited. After initialization switch to the 22.1184MHz crystal
frequency to reduce confusion and keep the setup option simple.
USAGE GUIDELINES AND INSTRUCTIONS
1. Safety
a. While the voltages used in this project are not dangerous, there may be a danger of damage to the
hardware due to excessive current flow. It is necessary to always connect this device to a power supply
that limits current to a safe level. Unsafe power supplies include devices such as car batteries.
b. Do not short any connectors as damage or fire may result.
c. Always verify that the drive wheels are off the ground before attempting to start the car’s motor. Also
ensure that the front wheels are free to turn.
2. Initial Setup / Components Identification.
a. It is necessary to supply only +5V power and ground to the car unit. Identify the 2 twisted-pair power
cables from the car. It has a red and a black plug, and the red plug is labeled with a voltage. The black plug
corresponds to the ground.
b. There are 3 DB-9 connectors on the CAN bus cable. The two male connectors have the correct pin-out to
interface to the C8051F040 development boards in the lab. The female connector follows OBD-II standard
pin-outs and is suitable for connection to certain other commercially available CAN devices. There are
various CAN cables with both male and female DB-9 connectors as well as splitter and multi-tap cables.
There are enough cable types to handle the worst-case configuration: 2 8051s, the car, and 2 PCs running
LabVIEW all connected on the CAN bus simultaneously. It should be noted that the 2 NI CAN cables with
female DB-9 connecter have terminating resistors on the end with the label. The CAN bus specifications
call for terminating resistors at both far ends of the physical bus. The car also has built-in terminating
resistors.
CAUTION: when attaching several devices to the CAN bus simultaneously make sure the bus isn’t
flooded with commands. The relatively slow bus configuration used here can only handle a limited
number of commands per second.
c. The order of power supply power-up sequencing is unimportant, but it is important to check all power
connections for correct voltage and polarity before turning on power.
3. Use of CAN Interface
a. 11-bit CAN message IDs are used for all communication.
b. The CAN interface on the car will receive messages with several message IDs. (See Appendix A.)
c. The CAN interface on the car transmits several messages with real-time data from sensors. (See Appendix
A.)
d. The C8051F040 development boards need to be plugged into the Control and Meter Modules to correctly
send and receive CAN information. Each 10-pin connector should be placed on the pins such that pin 1 of
the connector aligns with pin 1 of the port (except for the DAC - see 2b in Appendix B). This corresponds
to having the end of the connector with the ribbon on it facing the side that the power to the board comes
in on.
Vue de la page 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 20 21

Commentaires sur ces manuels

Pas de commentaire

Privileg 965.478 1/60053 manuels

Manuels d'utilisation et guides de l'utilisateur pour Fours Privileg 965.478 1/60053.
Nous fournissons des manuels en pdf 1 Privileg 965.478 1/60053 à télécharger gratuitement par type de document : Manuel de l'utilisateur






Plus de produits et de manuels pour Fours Privileg

Modèles Type de document
072517_60835 Manuel de l'utilisateur   Privileg 072517_60835 Benutzerhandbuch, 40 pages
EH51000X Manuel de l'utilisateur   Privileg EH51000X Benutzerhandbuch, 32 pages
86850W Manuel de l'utilisateur   Privileg 86850 Benutzerhandbuch, 48 pages
479.652 0/60198 Manuel de l'utilisateur   Privileg 479.652 0/60198 Benutzerhandbuch, 40 pages
735.559 7/8553 Manuel de l'utilisateur   Privileg 621.008 2/8555 Benutzerhandbuch [mk] [sq] , 44 pages
700.251 2/30398 Manuel de l'utilisateur   Privileg 700.251 2/30398 Benutzerhandbuch, 40 pages
080.856 8/30231 Manuel de l'utilisateur   Privileg 080.856 8/30231 Benutzerhandbuch [fr] , 56 pages
002.444 8/8687 Manuel de l'utilisateur   Privileg 002.425 7/8688 Benutzerhandbuch, 36 pages
EH250PYW Manuel de l'utilisateur   Privileg EH250PYX Benutzerhandbuch [fr] , 48 pages
884098_61060 Manuel de l'utilisateur   Privileg 832097_61062 Benutzerhandbuch, 48 pages
845724_60730 Manuel de l'utilisateur   Privileg 845724_60730 Benutzerhandbuch, 40 pages
755.295 3/30060 Manuel de l'utilisateur   Privileg 224.219 6/30062 Benutzerhandbuch, 40 pages
EH52500IX Manuel de l'utilisateur   Privileg EH52500IX Benutzerhandbuch, 48 pages
319108_60958 Manuel de l'utilisateur   Privileg 804988_60960 Benutzerhandbuch, 44 pages
600/063-50164 Manuel de l'utilisateur   Privileg 600/063-50164 Benutzerhandbuch, 40 pages
EH300PYB Manuel de l'utilisateur   Privileg 00264455_61147 Benutzerhandbuch, 48 pages
00412766_61344 Manuel de l'utilisateur   Privileg 00010085_61345 Benutzerhandbuch, 40 pages
648.166 7/60078 Manuel de l'utilisateur   Privileg 648.170 9/60077 Benutzerhandbuch, 40 pages
61800EW Manuel de l'utilisateur   Privileg 61800EALU Benutzerhandbuch, 52 pages
839.698 8/8514 Manuel de l'utilisateur   Privileg 839.698 8/8514 Benutzerhandbuch, 44 pages